Underground Cable Fault Detector and Locator Using Arduino
DOI:
https://doi.org/10.37591/jomtra.v6i1.2047Abstract
Abstract
In urban areas, electrical cables run underground instead of running over, because it does not get affected by any adverse effect of weather such as storm, snow, ice, heavy rainfall as well as pollution. While a fault occurs within the underground cable, it is difficult to detect the exact location of the fault for the repair process of the particular cable. This system can find the point of the exact location of a fault. This project uses the standard concept of Ohm's law, i.e., when a low dc voltage is applied at the end of feeder through series resistor (Cable lines), then the current would vary depending on the location of the fault of the cable. This prototype is assembled with a set of resistors representing cable length in kilometers and fault creation is made by a set of switches at every known kilometer (km) to cross check the accuracy of the same. This system uses an Arduino microcontroller, LCD and GSM. The relays are controlled by the relay driver IC which is used for switching the power sequentially to all the lines. The proposed technique is used not only for identification of fault but is also used to send detailed information about the fault to the authority using GSM. Also, it cuts the power supply on that particular location for the security of the people. It used to display the fault occurring at a particular distance and which displayed on 16×2 LCD, interfaced with the microcontroller.
Keywords: Arduino Uno, GSM modem, LCD, power cables, underground cables faults
Cite this Article
Sameer Jagtap, Dhembare Monika, Dake Pooja, Salunkhe Akshata. Underground Cable Fault Detector and Locator Using Arduino. Journal of Multimedia Technology & Recent Advancements. 2019; 6(1): 19–27p.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |