Connected Component Based Efficient Gait Recognition System
DOI:
https://doi.org/10.37591/joipprp.v4i2.988Abstract
Abstract
Gait recognition is one of the major security concerns for biometric authentication. In this work, an efficient gait recognition system using connected component based segmentation algorithm is proposed. This proposed system works on two different sub-phases, named as extraction phase and recognition phase. In the extraction phase, connected component based segmentation algorithm is applied on different gait images, taken from different sources and with the help of threshold value, decided with multiple experiments performed on gait image segments, the number of segments are reduced. While in recognition phase, artificial neural network is used. This proposed system helps to enhance the overhead problem of standard PCA algorithm. Experiments are carried out on different datasets, collected from CASIA dataset, which are in the form of silhouette images. Experimental results show that proposed system efficiency, in terms of recognition rate as well as time, is better than original PCA algorithm while reducing number of segments.
Keywords: Connected component, PCA algorithm, PCA, gait recognition, segmentation, threshold
Cite this Article
Yogesh Sharma, Manuj Mishra, Rajendra Singh Kushwaha. Connected Component Based Efficient Gait Recognition System. Journal of Image Processing & Pattern Recognition Progress. 2017; 4(2): 13–16p.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |